Fault phenomenon |
Cause |
Exclusion method |
1. Inaccurate pressure measurement |
(1) The damping hole is blocked, and the pointer of the pressure gauge jumps violently |
(1) Cleaning or oil change |
2. Increased internal leakage |
The valve port is too worn to be closed strictly, or the sealing surface is too worn, the clearance increases, and the internal leakage increases, so that the pressure at each measuring point is connected with each other |
Repair or replace worn parts |
3. Increased external permeability |
(1) Poor sealing at the pressure gauge interface |
(1) Refill the sealing material |